Font Size Change

HOMEIT Knowledge Center on emerging tech trendsDeliverables/ReportsSTAMP Workbench[Download]

PRINT PAGE

IT Knowledge Center on emerging tech trends

STAMP Workbench[Download]

Last updated on March 9, 2022
March 30, 2018
INFORMATION-TECHNOLOGY PROMOTION AGENCY, JAPAN
IT Knowledge Center

Manual
Development concept and operation policy
Installer
Version up
Source code
STAMP Workbench license
Sample file
JRE update
CONTACT US about STAMP Workbench

Inquiries will be accepted by email. Please contact the following e-mail address. IT Knowledge Center, Information-Technology Promotion Agency, Japan (IPA)
e-mail:

STAMP Workbench in Japanese version

Manual

STAMP Workbench Manual

Development concept and operation policy

■Concentrate on thinking
- As automated as possible.
- Analysts only need to focus on thinking. CS diagrams from the Component extraction table is automatically generated. Guided chart editing with intuitive operation is available.

■Help analysis. It's not just an editing tool.
- Automatic ID numbering (proactive support for repetitive analysis)
- Real-time Model collaboration
- Highlights of related information, parallel display

■Guide analysis procedure, but not limit operation.
- Step guidance window for beginners
- Available from any step for experts
- It can be used as a construction tool of CS Diagram.
- Two-way support of Diagram Table, and Table Diagram

■Intuitive operation
- The Look & Feel for a STAMP characteristic operation
- Consistent UI


Leaflet (1.03MB)

Installer

■MSI format installer
[64bits] stampworkbench-2_0_0-64bit-setup.zip (80.1MB)
[32bits] stampworkbench-2_0_0-32bit-setup.zip (80.6MB)

* These installers are the MSI format that is used as standard on Windows. Download the above zip file, unzip it, and run the MSI file.

■zip file
[64bits] stampworkbench-2_0_0-64bit.zip (91.3MB)
[32bits] stampworkbench-2_0_0-32bit.zip (92.1MB)

Version up

If you are already using STAMP Workbench, please uninstall or remove the old version and then install the new version.
Even if you uninstall the old version or delete the folder, the settings made in the old version will be automatically carried over to the new version.

* If there is a problem with the screen display
After installing the new version of STAMP Workbench, problems such as some characters becoming unreadable have been confirmed. When installing the latest version, if the files of the old version remain, this screen display problem may occur. This is because when you uninstall an older version, the uninstaller may not be able to remove the old files. This happens if you have previously installed by overwriting without uninstalling. If you encounter this issue, please try the steps below.

  1. Exit STAMP Workbench
  2. Uninstall with the uninstaller
  3. Completely delete the previously installed stampworkbench folder.
    (Folder with implicit setting is C: \ Program Files \ stampworkbench)
  4. Install STAMP Workbench again

In addition, it has been confirmed that some characters cannot be read when "High Contrast Mode" is enabled and "High Contrast: Black" is set in the Windows 10 settings. STAMP Workbench does not support automatic text / graphic color change in "High Contrast Mode". Try selecting the background, shape, line, and text colors in the Diagram Editor of [Tool] -> [System Property].

Source code

stamp-project-2_0_0.zip (2.1MB)
How to build (117KB)

STAMP Workbench license

Copyright © 2018 IPA
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

  1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer
  2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
https://opensource.org/licenses/BSD-2-Clauseanother window

astah license

http://astah.change-vision.com/platform/license.html another window

Sample file

This is a sample (STMP file) that was safely analyzed by STAMP Workbench. You can also use it as a template when you start using the STAMP Workbench.

Railroad_Crossing_Control_System.zip (10.8KB)

JRE update

STAMP Workbench uses the Java Runtime Environment (JRE) and includes the JRE in the installation package. If you have problems with STAMP Workbench operation due to the included JRE, you may be able to solve the problem by updating the JRE. This procedure manual describes the procedure for the user to update the JRE of the installed STAMP Workbench by yourself.
Please note that this procedure can be applied to STAMP Workbench Ver2.0.0 that includes Adopt Open JDK, and not to Ver 1.0.2 or earlier versions that include oracle JDK.

Update history

9 March 2022 Add a note about the cause and countermeasures of cases where some characters and figures may be difficult to see after version up.
30 September 2021 Update STAMP Workbench from version 1.0.2 to version 2.0.0.
Changed the included Java runtime environment from Oracle Java 8 to Adopt OpenJDK 8.
Change the executable format installer from exe format to MSI format and resume publishing the executable format installer.
Other minor fixes: Fixed other minor issues such as making it possible to edit .stmp files under the read only folder such as email attachments.
13 April 2021 Update STAMP Workbench from version 1.0.1 to version 1.0.2:
Fixed an issue where a memory leak could occur and freeze when a large amount of changes were made while editing. The undo / redo function supports 100 changes.
Other minor fixes: Fixed an issue where some parts were displayed smaller when displayed in a high resolution environment.
26 November 2019 Change STAMP Workbench installer from .exe format to .zip format
19 February 2019 Add build information files of STAMP Workbench.
How to build : Manual to build a STAMP Workbench software
stamp-project.zip : Source code tree which including build information files
1 October 2018 Update STAMP Workbench from version 1.0.0 to version 1.0.1 Fixed one issue:
 Substitute control characters (non-printing characters: “ACK”,“BEL”,“VT”,“FF”, etc.,)
 by caret notation or space (“^F”, “^G”, “ “, “ “, etc.,).
17 April 2018 Links within a page, CONTACT US about STAMP Workbench, Japanese page link, Development concept and operation policy, STAMP Workbench leaflet and a sample file are added.